4
SPECIFICATIONS
GENERATOR
Model
Design
Frequency
Rated Output (COP)
Rated Voltage
Phase & Wire
Power Factor
No. of Poles
Insulation
Voltage Regulation
Type of Coupling
DIESEL ENGINE
Model
Design
No. of cylinders
Bore x stroke
Displacement
Engine speed
Lubricating Oil
Oil capacity
Coolant capacity
SET
Fuel
Fuel consumption (at full load)
Fuel tank capacity
Continuous Operating Hours
Battery (V x Ah/5Hr)
Starting System
L x W x H (with wheel)
Approx Net Wt.
Terminal
Output
Receptacle
Option
Caster
Sound Level (full load at 7m)
Emergency Stop System
AMPS
AMPS
J116
Unit
-STD
Salient-pole, revolving-field AC generator
(AVR system with separate and self-excitation brush)
Hz
50
kVA
16
kW
16
V
220
1-2
φ-w
%
-
-
Rotary coil: Class F, Stator coil: Class B
%
Vertical, water-cooled, 4-cycle diesel engine
mm
L
rpm
3000
L
L
L
6.0
L
hrs
13.0
mm
kg
-
-
-
-
dB(A)
77.5
-
Oil pressure, water temperature, fan belt broken
A
72.7
-AUS
-STD
18.8
18.8
240
110/220
100
2
8 (No load to full load)
Direct coupled
V1305-BG-SEC
4
φ76 x 73.6
1.335
API service class CD or higher
5.7
3.5
Diesel fuel No. 2 (ASTM D975)
79
80D26R(S) (12V x 55Ah)
Electric
1300 x 611 x 922
380
-
-
In case of abnormal:
85.5 x 2
66.7
/85.5
J119
-SA
60
11.5/18.8
11.5/18.8
127/220
1-3
3600
7.5
10.5
-
-
82.0
90.6/85.5