NT4N64 PII and NT4N39 PIV Call Processor features

Buttons on the NT4N64 PII and NT4N39 PIV Call processor cards allow the
administrator to initialize and reset the system.
Initialize button
The manual initialize (Init) button associated with the active Call Server starts
the Initialize program. The Initialize program can clear some equipment
faults. It then rebuilds call-dependent data and generates system messages
indicating the status of the system. This process is called an initialization.
Reset button
You can cold restart the processor card with the Reset button. This is
equivalent to a full power start up of the processor card. The System
Loader initiates call processing and starts memory-checking diagnostics.
This process is called a system reload or sysload.
CP PIV faceplate LEDs
The CP PIV faceplate features the following 5 LEDs:
Copyright © 2007, Nortel Networks
.
CAUTION
SERVICE INTERRUPTION
Call processing is briefly interrupted during an initialization.
CAUTION
SERVICE INTERRUPTION
During a sysload, active calls are disconnected and the system
goes into an emergency line transfer state. Use the reset button
only when specifically instructed to do so in an NTP.
PWR – Solid Green – Power Good
CF – Flashing Green shows activity on compact flash cards CF1 or CF2.
HDD – Flashing Green shows activity on secondary IDE bus (not used)
LAN1 – ELAN Activity
LAN2 – HSP Activity
— Flashing Yellow – 10 MB
— Flashing Green – 100 MB
— Flashing Amber – 1000 MB (1 GB)
Nortel Communication Server 1000
Communication Server 1000E Maintenance
NN43041-700 01.02 Standard
Release 5.0 20 June 2007
Circuit card features 37