Chapter 2: Installing the system
2.5 Placing the terminal
2.5.1 Where to place the terminal
Temperature conditions
The terminal must be placed in a ventilated area with free space around all
sides of the unit, except the bottom side.
Ambient temperature range is –25°C to +55°C.
If the terminal is installed in a location where the ambient temperature may
exceed 50°C, we recommend placing the terminal where unintentional contact
is avoided. If the maximum ambient temperature does not exceed 50°C, the
terminal can be placed in a public area.
Grounding access
Important
The terminal is designed with a cabinet for bulkhead or desktop installation.
The cabinet is equipped with mounting brackets, making it possible to secure
the unit on a bulkhead.
See Outline dimensions, terminal on page 115 in Appendix B.
36
The terminal must be placed in an area where access to the
hull or equivalent grounding can be reached within 0.5 m.
Placing the terminal