Appendix C: Grounding and RF protection
C.9 Separate ground cable
C.9.1 Ground cable - construction
When dealing with electrical installations in a marine environment, all wiring
must be done with double insulated, tinned, high quality and if exposed also
UV resistant cables. This shall also apply to the separate ground cable
mentioned in the previous paragraphs.
The ground cable is constructed using an appropriate cable with a cross
section area of at least 6 mm
crimp terminals – see illustration below. The crimp terminals must be a
marine approved type e.g. the DuraSeal series from Raychem.
134
2
(AWG10) and terminated with insulated ring
Antenna:
M10 Insulated Ring Terminal
(Raychem, DuraSeal Series )
Terminal:
M4 Insulated Ring Terminal
(Raychem, DuraSeal Series )
Separate ground cable