Troubleshooting - Stihl MSA 160 C Instruction Manual

Hide thumbs Also See for MSA 160 C:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 54
English

Troubleshooting

Always remove the battery from the machine before starting any work on the machine.
Problem
Machine does not start when switched on
Machine switches off in operation
94
Cause
No electrical contact between machine
and battery
State of charge of the battery is too low
(1 LED on battery flashes green)
Battery too hot / too cold
(1 LED on battery is red)
Malfunction of battery
(4 LEDs on battery flash red)
Unit too hot
(3 LEDs on battery are red)
Electromagnetic fault or malfunction in
machine
(3 LEDs on battery flash red)
Moisture in the machine and/or battery
Battery or machine electronics too hot
Electrical or electromagnetic malfunction Remove battery and reinsert it
Remedy
Remove battery, visually inspect the
contacts and reinsert the battery
Charge battery
Let the battery cool down / let the battery
warm up gradually at temperatures of
approx. 15 °C - 20 °C (59 °F - 68 °F)
Remove the battery from the machine
and reinsert it. Turn on the machine – if
the LEDs still flash, the battery is faulty
and must be replaced
Let the machine cool off
Remove the battery from the machine.
Remove dirt from contacts in the battery
compartment with a blunt object. Rein-
sert the battery. Turn on machine – if the
LEDs still flash, the machine is faulty and
must be checked by a servicing dealer
Let the machine/battery dry
Remove battery from the machine, let
battery and machine cool off