Allocating heating circuits to the remote control

The heating circuit allocation must be
configured when commissioning the
Vitotrol.
Heating circuit
The remote control affects the heating circuit with-
out mixer A1
The remote control affects the heating circuit with
mixer M2
The remote control affects the heating circuit with
mixer M3
Note
One heating circuit can be assigned to
the Vitotrol 200A/200 RF.
Up to three heating circuits can be
assigned to the Vitotrol 300A/300 RF.
Up to 2 remote controls may be connec-
ted to the control unit.
If the heating circuit allocation is later
cancelled, reset coding address A0 for
this heating circuit to 0 (fault message
bC, bd, bE).
Function description
Vitotrol configuration
200A/200 RF
300A/300 RF
H 1
HC 1
H 2
HC 2
H 3
HC 3
127