Scalance Xb005G - Siemens SCALANCE XB-000 Operating Instructions Manual

Hide thumbs Also See for SCALANCE XB-000:
Table of Contents

Advertisement

7.8

SCALANCE XB005G

Table 7- 8
Technical specifications of the SCALANCE XB005G
Technical specifications
Order number
SCALANCE XB005G
Attachment to Industrial Ethernet
Quantity
Design
Properties
Transmission rate
Permitted cable lengths (Industrial
Ethernet)
0 to 55 m
0 to 85 m
0 to 100 m
Electrical data
Power supply
Current consumption
Power loss at 24 VDC
Overvoltage protection at input
Permitted ambient conditions
Ambient temperature
Relative humidity
Operating altitude
Design, dimensions and weight
Immunity
Emission
SCALANCE XB-000
Operating Instructions, 12/2015, A2B00077300-06
6GK5 005-0GA00-1AB2
5
RJ-45 jacks with MDI-X pinning
Half / full duplex
10 / 100 / 1000 Mbps
Alternative combinations per length range
Max. 55 m IE TP Torsion Cable 4x2 with IE FC RJ45 Plug 180 4x2
Max. 45 m IE TP Torsion Cable 4x2 with IE FC RJ45 + 10 m TP Cord 4x2 via
IE FC RJ45 Outlet
Max. 85 m IE FC TP Marine/Trailing Cable 4x2 with IE FC RJ45 Plug 180 4x2
Max. 75 m IE FC TP Marine/Trailing Cable 4x2 + 10 m TP Cord 4x2 via
IE FC RJ45 Outlet
Max. 100 m IE FC TP Standard Cable 4x2 with IE FC RJ45 Plug 180 4x2
Max. 90 m IE FC TP Standard Cable 4x2 + 10 m TP Cord 4x2 via
IE FC RJ45 Outlet
Rated voltage
Voltage range
Design
Typical
Typical
During operation
During storage
During transportation
During operation
During operation
EN 61000-6-2
EN 61000-6-4
Technical specifications
7.8 SCALANCE XB005G
24 VDC
19.2 to 28.8 VDC Safe Extra Low Voltage
(SELV)
3-terminal plug-in block
550 mA
13.2 W
PTC resettable fuse (1.0 A / 60 V)
-10 ℃ to +60 ℃
-40 ℃ to +80 ℃
-40 ℃ to +80 ℃
≤ 95 % no condensation
≤ 2,000 m above sea level at max. 56 ℃
ambient temperature
≤ 3,000 m above sea level at max. 50 ℃
ambient temperature
65