Appendix A. Remote Control Operation: Modem Switch; General; Message Structure; A.1 General - Comtech EF Data SMS-758 Installation And Operation Manual

Modem protection switch
Table of Contents

Advertisement

REMOTE CONTROL OPERATION:
This appendix defines the protocol and command structure for the "modem switch" style
of remote control and status monitoring of the EFData SMS-758 switch. With modem
switch software, when the switch detects either a modulator or demodulator failure on
the prime modem, both the modulator and demodulator functions will be switched to the
backup modem.

A.1 General

Remote controls and status information are transferred via an RS-485 (optional RS-232C)
serial communications link. For RS-232C communication, switch SP1-5 on the M&C
module must be turned ON.
Commands and data are transferred on the remote control communications link as
US ASCII-encoded character strings.
The remote communications link is operated in a half-duplex mode. Communications on
the remote link are initiated by a remote controller or terminal.
The switch never transmits data on the link unless it is commanded to do so.
A.2 Message Structure
The ASCII character format used requires 11 bits/character:
MN/SMS758 Rev. 3
Firmware number:
FW/0713-33J
Software version:
5.10
1 start bit
7 information bits
1 parity bit (odd/even)
2 stop bits
Appendix A.