Backup Modem Address; Prime Modem Interface Type; Backup Modem Interface Type - Comtech EF Data SMS-758 Installation And Operation Manual

Modem protection switch
Table of Contents

Advertisement

Remote Control Operation
A.3.3.2 Backup Modem Address
Address "0" may be used to clear the address field of modem "x".
Command:
Response:
Status Only: <add/ADD_Bx"cr"
Response:
A.3.3.3 Prime Modem Interface Type
Command:
Response:
Status Only: <add/INT_x"cr"
Response:
A.3.3.4 Backup Modem Interface Type
Command:
Response:
Status Only: <add/INT_Bx"cr"
Response:
A–6
<add/ADD_Bx_yyy"cr"
>add/ADD_Bx_yyy"cr""lf"]
>add/ADD_Bx_yyy"cr""lf"]
Where:
x = 1 to 8 (backup modem number).
yyy = 1 to 255 (backup modem address).
<add/INT_x_y"cr"
>add/INT_x_y"cr""lf"]
>add/INT_x_y"cr""lf"]
Where:
x = 1 to 8 (prime modem number).
y = 1 (for 15 D), 2 (for V.35), 3 (for RS422), 4 (for DCTN), 5 (for IDR), or 6 (for
OTHER).
<add/INT_Bx_y"cr"
>add/INT_Bx_y"cr""lf"]
>add/INT_Bx_y"cr""lf"]
Where:
x = 1 or 2 (backup modem number).
y = 1 (for DS1), 2 (for V.35), or 3 (for RS-422).