Points In Operation And How To Stop - Dolmar ME-246.4 Original Instruction Manual

Hide thumbs Also See for ME-246.4:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

POINTS IN OPERATION AND HOW TO STOP

CAUTION:
Observe the applicable accident prevention regulations!
NOTICE:
Remove the guide bar cover before starting the engine.
STARTING
Move at least 3 m away from the place of refuelling. Place the equipment on a clean piece of ground taking care that the attachment does not
come into contact with the ground or any other objects.
A: Cold start
1)
Set this machine on a flat space.
2)
Set the I-O switch (A) to OPERATION.
3)
Primer pump
Continue to push the primer pump (B) until fuel enters into the primer
pump.
(In general, fuel enters into the primer pump by 7 to 10 pushes.)
If the primer pump is pushed excessively, an excess of gasoline returns to
the fuel tank.
4)
Recoil starter
Pull the start knob gently until it is hard to pull (compression point). Then,
return the start knob, and pull it strongly.
Never pull the rope to the full. Once the start knob is pulled, never release
your hand immediately. Hold the start knob until it returns to its original
point.
5)
The handle equips with lock-off lever (C) to prevent accidental start. To
pull the throttle lever (D), grasp the handle to release the lock (the lock-off
button is pressed by hand pressure).
6)
Warm-up operation
Continue warm-up operation for 2 to 3 minutes.
Note: In case of excessive fuel intake, remove the spark plug and pull the starter handle slowly to remove excess fuel. Also, dry the electrode
section of the spark plug.
OPERATION
B
16
STOP
A
C
D

Advertisement

Table of Contents
loading

Table of Contents