Gate - dbx 260 User Manual

Complete equalization & loudspeaker management system
Hide thumbs Also See for 260:
Table of Contents

Advertisement

DriveRack
®
Section 4
Detailed Parameters
24-36Hz and 36-56Hz (Subharmonic Synthesis) Level - 0 to 100%
These controls individually let you customize the amount of the respective synthesized frequencies to be added in,
tuning the ultimate bass response of your system to taste. For example, if the sound is too woofy or growly, try turning
down the 36Hz-56Hz level. If your
woofers are bottoming out (making a ticking, popping sound), try turning down the 24Hz-36Hz level. You may find
that a setting produces fine results in one room, but produces too much boominess in another. If this occurs, adjust the
controls as needed, (e.g., decrease one or the other of the band levels). Experimentation will pay off with smooth, full,
deeply extended bass. Remember, you are not selecting a frequency. You are controlling the overall level of each band.

4.4 Gate

Gate On/Off
Local (per band control) or global on and off.
Threshold -50 to 20 dBu
The threshold is the volume level at which the gate opens. Anything above the threshold passes, while signal that is
lower than the threshold is attenuated. Beware, setting the threshold to high can cut off the tail end of signals as they
fade out (the sustain of a guitar note, a held piano chord, a reverb tail, etc.).
Ratio 1:1.0 to 1:15
This is where you decide how much downward expansion you want. This ratio works opposite from that of the
compressor or limiter. If a ratio of 1:4 is selected, a signal that is 1dB below the threshold will be reduced in gain so that
it becomes 4dB below the threshold.
Attack 0.1 to 200 m Sec
As the signal reaches the threshold area, the Attack control sets the speed at which the gate opens. Use very fast attack
times to catch the fronts of transient signals.
Hold 0 to 500 m Sec
The Hold control sets the amount of time the gate is held open after the signal passes below the threshold point.
Release 360 to 5 dB
Release sets the speed at which the gate "closes" or attenuates when the end of the Hold time is reached.
Max ATT 0 to Inf. dB
This sets the maximum amount of attenuation for the gate.
30