Section 4 - Detailed Parameters; Pre-Crossover Eq (28-Band Geq Or 9-Band Peq) - dbx 260 User Manual

Complete equalization & loudspeaker management system
Hide thumbs Also See for 260:
Table of Contents

Advertisement

DriveRack
®
Section 4
Detailed Parameters
SECTION 4 – DETAILED PARAMETERS
The DriveRack 260 offers complete editing flexibility, by offering in-depth control over every parameter within each
effect module. The following section will provide you with descriptions and explanations of all parameters within the
DriveRack 260.

4.1 Pre-Crossover EQ (28-Band GEQ or 9-Band PEQ)

The DriveRack 260's Pre-Crossover EQ section may be configured as a single or linkable 28 band graphic EQ or 9-Band
Parametric EQ.
GEQ
EQ On/Off
Turns the EQ on and off.
Flatten/Restore
This parameter either flattens the GEQ settings (sets all bands to 0 dB) or restores (think of this as 'undo') the GEQ to
the last settings before flattening. The DriveRack unit allows you to leave the EQ edit window and return without losing
the edited EQ settings.
Frequency (F) 31.5Hz to 16.0kHz
This parameter allows you to select any one of the 28 available frequency bands.
Gain (G) -12 to +12 dB
This parameter allows you to adjust the level of any one of the 28 bands of the GEQ in .5 dB increments.
PEQ
EQ On/Off
Turns the PEQ on and off.
Flat Set/Undo
This parameter either flattens (sets all bands to 0 dB) or restores (think of this as 'undo') all bands to their original
settings.
Band 1 Frequency 20 to 20kHz (Low Shelf)
Selects the frequency of the low pass shelf parametric EQ.
Slope 1 3-12dB/Octave
Sets the slope of the low shelf parametric EQ.
Level 1 -12 to 12 dB
Sets the overall gain of the shelf EQ.
Band (2-8) Frequency 20 to 20k
Selects the frequency of the selected band of the parametric EQ.
Q (2-8) 0.20 to 16.0
Adjusts the Q of the selected band of the parametric EQ.