Information Regarding The System Hydraulics - Wolf CFK-1 Installation, Operating And Maintenance Instructions

Table of Contents

Advertisement

Information regarding
the system hydraulics
Pressure drop, CFK-1 with ANRO 30 °C
8

Information regarding the system hydraulics

The collectors can be operated with a high specific flow rate (so-called
High-Flow). A dvantages: The collector is well cooled = high collector efficiency
level, low heat losses at the flow line. Disadvantages: High pressure drop
= powerful pump, large pipe cross-sections.
The collectors can be operated with a low specific flow rate (so-called
Low-Flow). Here, the advantages and disadvantages are reversed compared
to the High-Flow operation. An additional advantage, due to the higher flow
temperature, is the effective operation of a stratification cylinder.
Flow data: High-Flow (90 l/h x coll), ANRO 30 °C
Collector
Solar line
number
length (m)
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
All details are recommendations and may vary from system to system. The
expansion vessel sizes stated are valid for a static head of up to 10 metres only.
Solar pipe Ø
Pump
(mm)
group
20
12 x 1
10
60
15 x 1
10
30
15 x 1
10
60
18 x 1
10
30
18 x 1
10
60
22 x 1
10
30
18 x 1
10
60
22 x 1
10
30
18 x 1
10
60
22 x 1
10
20
18 x 1
10
60
22 x 1
10
30
22 x 1
10
60
28 x 1,5
10
30
22 x 1
10
90
28 x 1,5
10
25
22 x 1
10
80
28 x 1,5
10
Flow rate per collector (l/h)
Expansion
vessel 2.5
DHW cylinder
bar
(l)
SEM-2-300
18
SEM-2-300
18
SEM-2-400
25
SEM-2-400
25
SEM-1-500
35
SEM-1-500
35
SEM-1-750
35
SEM-1-750
50
SEM-1-750
50
SEM-1-750
50
SEM-1-1000
50
SEM-1-1000
50
SEM-1-1000
80
SEM-1-1000
80
SEM-1-1000
80
SEM-1-1000
80
SEM-1-1000
80
SEM-1-1000
80