6.1.9
Home
position
(HP)
interrupter
Refer
to
Fig. 6.1
1,
turn printer
power
on,
after initialization
cycle
is
complete
check
for a clearance
of
0.8
inch
to 0.9
inch (20.5
to
22.5
mm)
between
the
left
frame
of the base
and
the
left
carriage side
frame.
(
1
)
Turn
printer
power
off.
Move
the
carriage
to the
right
and
loosen the
two
setscrews
which
hold
the
HP
interrupter.
If
the clearance
measured
in
the
check procedure was too
small,
move
the
HP
interrupter
slightly
to the
right,
re-tighten
the screws
and
recheck
the
clearance.
If
the clearance
measured was
too
large,
move
the
HP
interrupter
slightly
to
the
left
and
recheck.
Fig.
6.11
-