Removing the Top Enclosure

The following procedure assumes that you have completed Steps 1–4 in PC3x Bottom.
Removing the top enclosure requires removing the left and right endcaps. Each endcap includes
the endcap, endcap side bracket and endcap locking bracket.
Endcap Side Bracket
Figure 3-2
1. Refer to Figure 3-3.
2. Remove the four screws that secure the endcaps to the rear panel.
Figure 3-3
3. Refer to Figure 3-1. Move the unit so that one end hangs over the edge of your work
surface.
4. Remove the endcap locking bracket screw from the bottom enclosure.
Caution: When you remove the endcap locking bracket screw, the endcap locking bracket may
remain loosely in the endcap. However, it can come out of the endcap. When you remove the
screw securing the endcap locking bracket, hold it in position so that it does not fall out of the
endcap and become lost or damaged.
5. Remove the remaining three screws and set the endcap safely aside.
6. Repeat for the other endcap.
Endcap
Endcap Locking Bracket
Endcap assembly
Endcap screws
Endcap screws
PC3x rear panel