Troubleshooting - Husky H1504FK-R Operator's Manual

4 gallon oil free portable stack tank air compressor
Table of Contents

Advertisement

Available languages

Available languages

Problem
Air leak near top of tool or in trigger
area.
Tool does nothing or operates
sluggishly.
Air leak near bottom of tool.
Tool jams frequently.
Air leaking at trigger valve.
Air leaking between housing and nose. Loose screws in housing.
Air leaking between housing and cap.
Nailer skips driving nail.
Other

TROUBLESHOOTING

Possible Cause(s)
Loose screws.
Worn or damaged o-rings or seals.
Inadequate air supply.
Worn or damaged O-rings or seals.
Loose screws.
Worn or damaged O-rings or bumper.
Incorrect fasteners.
Damaged fasteners.
Magazine or nose screw loose.
Magazine is dirty.
Driver is worn or damaged.
O-rings in trigger valve housing are
damaged.
Damaged O-rings.
Damage to bumper.
Loose screws.
Damaged gasket.
Worn bumper.
Dirt in nose piece.
Dirt or damage prevent nails or pusher
from moving freely in magazine.
Damaged pusher spring.
Inadequate air flow to nailer.
Worn O-ring on piston or lack of
lubrication.
Damaged O-ring on trigger valve.
Air leaks.
Cap gasket leaking.
29
Solution
Tighten screws.
Replace with good o-rings or seals.
Verify screws.
Replace with good o-rings or seals.
Tighten screws.
Replace with good o-rings or bumper.
Verify fasteners of correct size.
Replace damaged fasteners.
Tighten screws.
Clean screws.
Install "DRIVER" maintenance kit.
Replace O-rings. Check operation of
Work Contact Element (WCE).
Tighten screws.
Replace O-rings.
Replace bumper.
Tighten screws.
Replace gasket.
Replace bumper.
Clean drive channel.
Clean magazine.
Replace spring.
Check fitting, hose or compressor.
Replace and lubricate O-rings.
Replace O-rings.
Tighten screws and fittings.
Replace gasket.
Contact your local dealer for service.

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents