Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Stationary Air Compressor
Table of Contents
Description . . . . . . . . . . . . . . . . . . . . . 1
Unpacking . . . . . . . . . . . . . . . . . . . . . . 1
Safety Guidelines . . . . . . . . . . . . . . . . 1
General Safety Information . . . . . . . . 1
Introduction . . . . . . . . . . . . . . . . . . . . 3
Installation . . . . . . . . . . . . . . . . . . . . . 3
Assembly . . . . . . . . . . . . . . . . . . . . . . . 5
Operation . . . . . . . . . . . . . . . . . . . . . . 6
Maintenance . . . . . . . . . . . . . . . . . . . . 6
Troubleshooting Chart . . . . . . . . . . . . 8
Warranty . . . . . . . . . . . . . . . . . . . . . . 10
Description
Air compressor units are intended
to provide compressed air to power
pneumatic tools and operate spray
guns . The pumps supplied are oil
lubricated . A small amount of oil
carryover is present in the compressed
air stream . Applications requiring air
free of oil or water should have the
appropriate filter installed . The air
compressor unit must be mounted
as described in the instructions on
a solid floor . Any other use of these
units will void the warranty and the
manufacturer will not be responsible
for problems or damages resulting from
such misuse .
Unpacking
After unpacking the unit, inspect
carefully for any damage that may
have occurred during transit . Make sure
to tighten fittings, bolts, etc ., before
putting unit into service .
ReAD & FOllOW All InSTRUCTIOnS
SAVe TheSe InSTRUCTIOnS
DO nOT DISCARD
© 2009
Safety Guidelines
This manual contains information
that is very important to know and
understand . This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS . To help
recognize this information, observe the
following symbols .
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
information, that if not followed, may
cause damage to equipment.
nOTe: Information that requires special
attention .
General Safety Information
CAlIFORnIA pROpOSITIOn 65
contain chemicals known to the State
of California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
dust when you cut, sand, drill
or grind materials such as
wood, paint, metal, concrete,
cement, or other masonry. This dust
often contains chemicals known to
cause cancer, birth defects, or other
reproductive harm. Wear protective
gear.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
Stationary Single Stage Vertical Air Compressors
This compressor/pump is nOT
equipped and should nOT be
used "as is" to supply breathing
quality air. For any application of
air for human consumption, you
Danger indicates an
must fit the air compressor/pump
imminently
with suitable in-line safety and
alarm equipment. This additional
equipment is necessary to
properly filter and purify the air
Warning indicates a
to meet minimal specifications for
potentially
Grade D breathing as described
in Compressed Gas Association
Commodity Specification G 7.1,
Caution indicates a
OShA 29 CFR 1910. 134, and/or
potentially
Canadian Standards Associations
(CSA).
DISClAIMeR OF WARRAnTIeS
In the event the compressor is
Notice indicates
used for the purpose of breathing
important
air application and proper in-
line safety and alarm equipment
is not simultaneously used,
existing warranties are void, and
the Manufacturer disclaims any
liability whatsoever for any loss,
personal injury or damage.
This product or
GeneRAl SAFeTy
its power cord may
Since the air compressor and other
components (material pump, spray
guns, filters, lubricators, hoses, etc .)
used, make up a high pressure pumping
You can
system, the following safety precautions
create
must be observed at all times:
1 . Read all manuals included
Breathable Air Warning
with this product
carefully . Be thoroughly
familiar with the controls
and the proper use of the
equipment .
IN625701AV 12/09
MANUAL

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Husky VT631402AJ

  • Page 1 See Warranty on page 10 for important information about commercial use of this product. Stationary Single Stage Vertical Air Compressors Operating Instructions Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information.
  • Page 2: General Safety Information

    Operating Instructions General Safety Information 14 . Tanks rust from moisture build-up, (Continued) which weakens the tank . Make sure Compressor parts may be hot to drain tank regularly and inspect 2 . Follow all local electrical and safety even if the unit is stopped. periodically for unsafe conditions codes as well as in the United States, such as rust formation and corrosion .
  • Page 3 Stationary Single Stage Vertical Air Compressors Introduction MOUnTInG Discharge Tube Belt Guard Never use the wood Refer to Figure 1 . shipping skids for InSTAllInG A ShUT-OFF VAlVe mounting the compressor. Check Valve A shut-off valve should be installed FLOOR MOUNTING (ALL UNITS) on the discharge port of the tank to Pressure The compressor feet MUST be bolted to...
  • Page 4: Electrical Installation

    Operating Instructions Installation WIRInG 2 . A voltage meter . (Continued) Local electrical wiring codes differ from electrical Installation area to area . Source wiring, plug and protector must be rated for at least wiring and electrical connections the amperage and voltage indicated must be performed by on the motor nameplate, and meet a qualified electrician...
  • Page 5: Assembly

    Stationary Single Stage Vertical Air Compressors Oil Fill Cap (Dispose of properly) Dipstick Breather Breather Add Oil Remove Cap Oil Drain Extension* Cap* Full Full Dipstick Oil Read Sight Glass Figure 8 * Not included with all models. Install Breather Install Dipstick Figure 7 Breather...
  • Page 6: Operation

    Operating Instructions Operation 2 . Open the tank drain valve . Turn outlet valve to open air flow . START-Up / BReAk-In pROCeDURe 3 . Move pressure switch lever or knob Do not attach air to the OFF position and plug in tools to open end of power cord .
  • Page 7: Maintenance Schedule

    Stationary Single Stage Vertical Air Compressors Maintenance (Continued) MAInTenAnCe SCheDUle 6 . Check belt for signs of excessive OpeRATIOn DAIly Weekly MOnThly 3 MOnThS wear . If belt shows signs of wear, CHECK OIL LEVEL replace it . Check belt for proper DRAIN TANK tension / alignment .
  • Page 8: Troubleshooting Chart

    Operating Instructions Troubleshooting Chart Symptom possible Cause(s) Corrective Action Low discharge pressure 1 . Air demand exceeds pump capacity 1 . Reduce air demand or use a compressor with more capacity . 2 . Restricted air intake 2 . Clean or replace the air filter element . 3 .
  • Page 9 Stationary Single Stage Vertical Air Compressors Troubleshooting Chart (Continued) Symptom possible Cause(s) Corrective Action Reset mechanism cuts 1 . Lack of proper ventilation / room 1 . Move compressor to well ventilated area out repeatedly or circuit temperature too high breaker trips repeatedly 2 .
  • Page 10: Warranty

    Operating Instructions Limited Warranty 1 . DURATION: From the date of purchase by the original purchaser as follows: One Year, Two Years, Three Years, Four Years, or Five Years as indicated on product specification label . 2 . WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400 3 .
  • Page 11: Table Of Contents

    Voir la Garantie à la page 20 pour de l’information importante sur l’utilisation commercial de ce produit. Compresseurs d'air vertical fixes monophases Instructions d’Utilisation Veuillez lire et conserver ces instructions. Lire attentivement avant de commencer à assembler, installer, faire fonctionner ou entretenir l'appareil décrit.
  • Page 12 Instructions d’utilisation Généralités sur la Sécurité 9 . Ne pas porter des vêtements Purger le liquide du réservoir (Suite) flottants ni des bijoux qui peuvent se quotidiennement. prendre dans les pièces mobiles du 1 . Lire attentivement tous 14 . L’accumulation d’humidité cause la modèle .
  • Page 13: Introduction

    Compresseurs d'air vertical fixes monophases Introduction Installation Discharge Tube Tuyau de décharge Belt Guard Carter de courroie Se référer à la Figure 1 . Débrancher, étiquetter et InSTAllATIOn D’Une SOUpApe Check Clapet verrouiller la source de Valve D’ARRêT puissance, ensuite dissiper Une soupape d’arrêt devrait être toute la pression du système avant Pressure...
  • Page 14 Instructions d’utilisation Installation InSTAllATIOn De FIlS (Suite) Les codes locaux concernant TUyAUTeRIe l’installation de fils varient d’endroit en Ne jamais utiliser les tuyaux en endroit . Les fils d’alimentation, fiches plastique (CPV) pour l’air comprimé. et le protecteur doivent être classifiés Ceci peut causer des blessures graves ou pour au moins le minimum d’ampérage la mort.
  • Page 15: Montage

    Compresseurs d'air vertical fixes monophases Oil Fill Cap Bouchon (Dispose of (Éliminer properly) Reniflard de Dipstick correctement) Breather réglette- Breather Reniflard jauge Ajoutez Add Oil l’huile Retirer le bouchon Oil Drain Extension* Rallonge de vidange d’huile * Cap* Bouchon * Plein Full Plein...
  • Page 16: Fonctionnement

    Instructions d’utilisation Functionnement 3 . Vérifier si le filtre d’air est propre . Enlever le couvercle du carter de DéMARRAGe / pROCéDURe De filtre, enlever le filtre et le laver avec RODAGe de l’eau chaude et savonneuse (ne Ne pas brancher pas laver les filtres en papier) .
  • Page 17 Compresseurs d'air vertical fixes monophases hORAIRe D’enTReTIen OpéRATIOn QUOTIDIen heBDOMAD AIRe MenSUel 3 MOIS VÉRIFIER LE NIVEAU D’HUILE PURGER LE RÉSERVOIR VÉRIFIER LE FILTRE à AIR VÉRIFIER LA SOUPAPE DE SûRETÉ NETTOYER LE MODÈLE VÉRIFIER LE SERRAGE DES COURROIES CHANGER L’HUILE entretien (Suite) e .
  • Page 18: Guide De Dépannage

    Instructions d’utilisation Guide De Dépannage Symptom possible Cause(s) Corrective Action Pression de décharge 1 . Demande d’air dépasse la capacité 1 . Diminuer la demande d’air ou utiliser un compresseur de plus basse de la pompe haute capacité . 2 . Arrivée d’air limitée 2 .
  • Page 19 Compresseurs d'air vertical fixes monophases Guide De Dépannage (Suite) Symptom possible Cause(s) Corrective Action Le moteur ronronne et 5 . Fonctionnement défectueux du 5 . Remplacer le clapet . fonctionne lentement ou clapet Ne pas démonter le clapet si le réservoir est pressurisé...
  • Page 20: Garantie

    Instructions d’utilisation garantie Limitée 1 . DURÉE: à partir de la date d’achat par l’acheteur original comme suit : Un An, Deux Ans, Trois Ans, Quatre Ans ou Cinq Ans comme indiqué sur l’étiquette de caractéristiques du produit . 2 . GARANTIE ACCORDÉE PAR (GARANT) : Campbell Hausfeld/Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Téléphone: (800) 543-6400 .
  • Page 21: Descripción

    Ver la Garantía en página 30 para información importante sobre el uso comercial de este producto. Compresor de aire vertical, fijo, de una fase Manual de Instrucciones de Operación Por favor lea y guarde estas instrucciones. Léalas cuidadosamente antes de tratar de montar, instalar, operar o dar mantenimiento al producto aquí...
  • Page 22: Informaciones Generales

    Manual de Instrucciones de Operación Informaciones Generales de 14 . Los tanques se oxidan debido a la piezas acumulación de humedad . Cerciórese Seguridad (Continuación) del compresor podrían estar de drenar el tanque con regularidad 1 . Lea con cuidado todos calientes inclusive si la e inspéccionelo periódicamente para los manuales incluídos...
  • Page 23: Introducción

    Compresor de aire vertical, fijo, de una fase Introducción No coloque la entrada de aire del Tapa protectora Discharge Tube Tubo de descarga compresor en un área donde haya Belt Guard de bandas Vea la Figura 1 . vapor, se rocíe pintura o arena o haya pARA InSTAlARle UnA VAlVUlA De ningún otro tipo de contaminación .
  • Page 24 Manual de Instrucciones de Operación Instalación (Continuación) Tamaños mínimos de cable Line Motor Linea Motor (la mayoría cumplen con todos Instalaciones eléctricas los códigos) Todo el Hasta 1,9 m (75 pies) cableado 240V 12AWG de largo e instalaciones eléctricas deberán ser realizados por Mayor que 1,9 m 10AWG un electricista calificado...
  • Page 25: Ensamblaje

    Compresor de aire vertical, fijo, de una fase Oil Fill Cap El tapón (Desechar (Dispose of apropiadamente) properly) Reniflard de Dipstick Breather réglette- Breather Respiradero jauge ó Para añadirle Add Oil el aceite Retire el tapón Extensión del drenaje de aceite * Oil Drain Extension* Cap* Tapón *...
  • Page 26: Funcionamiento

    Manual de Instrucciones de Operación Funcionamiento 3 . Cerciórese de que el filtro esté limpio . Para darle servicio al filtro pRepARACIOn pARA el USO / deberá destaparlo . Desconecte el pROCeDIMIenTO De ABlAnDe filtro y límpielo con agua caliente No conecte las Palanca - Automático enjabonada (Los filtros de papel no...
  • Page 27 Compresor de aire vertical, fijo, de una fase MAnTenIMIenTO SeRVICIO neCeSARIO DIARIAMenTe SeMAnAlMenTe MenSUAlMenTe TRIMeSTRAlMenTe MIDA EL NIVEL DE ACEITE DRENE EL TANQUE CHEQUÉE EL FILTRO DE AIRE CHEQUÉE LA VáLVULA DE SEGURIDAD LIMPIE LA UNIDAD CHEQUÉE LA TENSIóN DE LAS BANDAS CáMBIELE EL ACEITE Mantenimiento 7 .
  • Page 28: Guía De Diagnóstico De Averías

    Manual de Instrucciones de Operación Guía de Diagnóstico de Averías problema posible(s) Causa(s) Acción a Tomar Baja presión de descarga 1 . La demanda de aire excede la 1 . Reduzca la demanda de aire o utilice un compresor de mayor capacidad de la bomba capacidad .
  • Page 29 Compresor de aire vertical, fijo, de una fase Guía de Diagnóstico de Averías (Continuación) problema posible(s) Causa(s) Acción a Tomar El motor zumba y 4 . Malfuncionamiento del 4 . Reemplace el interruptor de presión . funciona lentamente o no interruptor presión, los contactos funciona en lo absoluto no se cierran...
  • Page 30: Garantía

    Manual de Instrucciones de Operación garantía Limitada 1 . DURACIóN: A partir de la fecha de compra por el comprador original tal como se especifica a continuación: Un Año, Dos Años, Tres Años, Cuatro Años o Cinco Años como se indica en la etiqueta de características del producto . 2 .
  • Page 31 notes / notas...
  • Page 32 Operating Instructions / Instructions d’utilisation / Manual de Instrucciones de Operación notes / notas...

This manual is also suitable for:

Vt631402

Table of Contents