Inserting The Cables - Viessmann VITOCAL 242-G Installation And Service Instructions Manual

Compact energy tower for low energy houses
Hide thumbs Also See for VITOCAL 242-G:
Table of Contents

Advertisement

Installation sequence
Inserting the heat pump
5. Note
Observe information regarding the
brine connection on page 98.
Insert the corrugated pipes of the
connection set for the brine circuit
(supplied with the heat pump) into
the pipe sleeves of the heat pump
and secure them with the clips
supplied.
Note
Do not shorten the corrugated
pipes. It will not be possible to
seal the connector at the shor-
tened end of the corrugated pipe.
Installation information brine
circuit connection set

Inserting the cables

When routing the on-site connecting
cables, observe the position of the
cable entries into the equipment (in
the equipment lid, see page 10 and
the following figure) as well as the
recommended positions of the outlet
areas for the hydraulic and brine con-
nections (see page 98).
64
(cont.)
6. Fit the l.h. retaining panel with the
special stud.
7. Fit the crossbar.
8. Level the unit.
Allow for a cable length of 1300 mm
inside the device (from the cable
entry to the electrical terminal array)
for connecting on-site cables inside
the device.