Viessmann VITOCAL 242-G Installation And Service Instructions Manual page 220

Compact energy tower for low energy houses
Hide thumbs Also See for VITOCAL 242-G:
Table of Contents

Advertisement

Commissioning/service reports
Control parameter report
Setting parameters
Room temperature
hook-up
Start optimisation
Max. flow correction
Room temperature
control
Heating curve level
Heating curve slope
Integral room tempera-
ture controller
Flow T excess
Mixer runtime
Mixer parameters
Screed function
Mixer active zone
Mixer dead zone
Natural cooling
Cooling limit > T room
Cooling curve level
Slope, cooling curve
Natural cooling with
mixer
Active zone natural
cooling
mixer
Dead zone natural
cooling
mixer
Cooling mixer runtime
Cooling mixer para-
meters
Heating water buffer cylinder
Buffer cylinder
Buffer cylinder pro-
gram
Fixed temperature
Temperature hyster-
esis
Max. temperature
Stop optimisation
*1
0: Never; 1: only reduced mode; 2: only standard mode; 3: in reduced and standard
mode.
220
(cont.)
Setting range
*
0 to 3
1
No/Yes
0.1 to 10.0 K
No/Yes
15 to 40 K
0.0 to 3.5
5 to 1000
10 to 40 K
0:05 to 4:15 min
0/1
0 to 15
2 to 40 K
0.5 to 3 K
No/Yes
2 to 20 K
-15 to 40
0.0 to 3.5
No/Yes
2 to 40 K
0.5 to 3 K
0:05 to 4:15 min
0/1
No/Yes
7-day program
1 to 60 °C
2 to 20 K
1 to 70 °C
No/Yes
Standard
Commission-
setting
ing
No
10.0 K
No
0 K
0.6
100
0 K
0:10 min
0
0 (passive)
4 K
1 K
No
4 K
0
1.2
No
4 K
1 K
0:10 min
0
No
OFF
50 °C
5 K
60 °C
Yes