Viessmann VITOCAL 242-G Installation And Service Instructions Manual page 126

Compact energy tower for low energy houses
Hide thumbs Also See for VITOCAL 242-G:
Table of Contents

Advertisement

Troubleshooting
Control unit diagnostics
Fault messages
38
Primary in
sensor
40
Heating circuit
2 flow sensor
(mixer circuit)
44
Natural cool-
ing flow sen-
sor
48
Heating circuit
2 flow sensor
4C
Natural cool-
ing flow sen-
sor
50
DHW sensor
top
52
DHW sensor
bottom
58
DHW sensor
top
5A
DHW sensor
bottom
60
Buffer cylinder
sensor
61
Secondary re-
turn sensor
68
Buffer cylinder
sensor
69
Secondary re-
turn sensor
92
Solar collector
sensor
93
Solar return
sensor
9A
Solar collector
sensor
9B
Solar return
sensor
A4
Check valve
126
(cont.)
Cause
Lead broken
Short circuit
Lead broken
Short circuit
Lead broken
Short circuit
Lead broken
Short circuit
Lead broken
The check valve is stuck or
faulty; the solar circuit cir-
culates during the night
Measures
Check the terminals and re-
place the sensor, if required
Check the sensor and re-
place, if required
Check the terminals and re-
place the sensor, if required
Check the sensor and re-
place, if required
Check the terminals and re-
place the sensor, if required
Check the sensor and re-
place, if required
Check the terminals and re-
place the sensor, if required
Check the sensor and re-
place, if required
Check the terminals and re-
place the sensor, if required
Check the check valve and
replace, if required