Viessmann VITOCAL 242-G Installation And Service Instructions Manual page 60

Compact energy tower for low energy houses
Hide thumbs Also See for VITOCAL 242-G:
Table of Contents

Advertisement

Installation sequence
Heat pump preparation
1. Remove the front part of the ther-
mal insulation.
2. Remove the top part of the thermal
insulation.
3. Insert the strain relief with inserted
cables (lying at the bottom of the
thermal insulation) into the groove
of the recess in the lower part of
the thermal insulation.
60
(cont.)
4. Check the floor area, valves and all
visible solder joints of the heat
pump for traces of oil.
Note
Traces of oil indicate a leaking
refrigerant circuit. Ask a refrigera-
tion engineer to check the heat
pump.