National Instruments SCXI-1321 Installation Manual page 10

Offset-null and shunt-calibration high-voltage terminal block
Hide thumbs Also See for SCXI-1321:
Table of Contents

Advertisement

SCXI-1121
+
R
1
+
4.5 kΩ
V
EX
4.5 kΩ
R
2
Note: R
and R
are completion resistors.
1
2
SCXI-1321 Terminal Block Installation Guide
Assuming a strain-gauge range with a gauge factor of GF = 2 and a
quarter-bridge configuration, this range corresponds to ±1,498 µε, as given
by the strain formula for a quarter-bridge strain-gauge configuration:
where
strained voltage static unstrained voltage
V
=
------------------------------------------------------------------------------------------------------- -
r
SCXI-1321
CH+
CH+
R
SCAL
301 kΩ
CH–
EX+
R
Trim
10 kΩ
39.1 kΩ
EX–
4V
ε
=
-------------------------------
(
GF 1
+
V
exc
CH+
CH–
EX+
R
Null
EX–
R
Trim
Figure 3. Quarter-Bridge Nulling Circuit
10
r
)
2V
r
Transducer
R
L
EX+
R
R
L
R
L
R
(dummy)
3
(Screw Adjusts Potentiometer)
(gauge)
4
CH+
ni.com

Advertisement

Table of Contents
loading

Table of Contents