Chapter 6
Digital Input and Output

Connecting Digital I/O Signals

P1.VCC
P1.0
P1.1
P1.GND
P0.0
P0.GND
NI 6238/6239 User Manual
The DI signals P0.<0..5> are referenced to P0.GND and DO signals
P1.<0..3> are referenced to P1.GND.
Figures 6-1 and 6-2 show P0.<0..5> and P1.<0..3> on the NI 6238 and the
NI 6239 device, respectively. Digital input and output signals can range
from 0 to 30 V. Refer to the NI 6238/6239 Specifications for more
information.
Figure 6-1. NI 6238 Digital I/O Connections (DO Source)
P1.<0..3>
Digital
Isolators
P1.GND
P0.GND