4. Attach the fan assembly to the fan bracket provided in the
log box. Use #10 sheet metal screws provided with fan
kit. Do not remove finger guard screws. (Fig. 9)
Fig. 9 - Attach the fan assembly to the fan bracket.
5. Connect snapstat leads. Disconnect the snapstat module
from the leads inside the snapstat bracket. (Fig. 10)
ST669
Bend open the snapstat bracket. Use needlenose pliers
RUVSOD
to remove the black plastic grommet from the bracket.
attach fan to bracket
Discard the bracket. Insert the grommet and wires into the
7/01
large hole at the bottom right corner of the inner shroud.
Feed the snapstat wire leads through the grommet into the
stove interior. Connect the two wires to the two snapstat
extension leads attached to the inner shroud.
Snapstat Bracket
Fig. 10 - Remove the snapstat and grommet from the bracket and
insert the grommet into the inner shroud.
ST640
RUVSOD
snapstat
7/01
10
Snapstat
Wire
Rheostat
Wire
Fan
Bracket
Finger Guard
Snapstat Module
Pinch
Grommet
to Remove
6. Position the fan assembly so the ducts slide between the
inner and outer shroud. The inner shroud should engage
with the two slots in the ends of the bracket so that bracket
and shroud are interlocked. (Fig. 11) Secure the bracket
with the four sheet metal screws provided in the finish
bag.
7. Route the rheostat wire assembly to the right between the
inner and outer shroud. Run the wire through the slots at
the bottom right corner of the inner shroud.
8. Refasten the outer shroud to the inner duct assembly.
Outer
Shroud
Fig. 11 - Position the fan to engage the inner shroud with the fan
bracket slots and secure with sheet metal screws.
ST194
9. Install the snapstat by loosening the front screw on the
attach fan to shroud
11/99
inner side of the duct (Fig. 12) slide the snapstat under
the head of the screw and tighten. Connect the leads
to the snapstat. Make sure the snapstat assembly is
mounted straight front to back.
10. Slide shroud assembly over the sides and fasten the four
screws loosened earlier.
Left Air Duct
Fig. 12 - Install the snapstat and connect the extension wire
terminals. View is with top removed, however, access is available
through the rear when installing fan before gas line connection.
ST195
attach snapstat
11/99
Slot
{Inner Shroud}
Slot
Snapstat
30005056