7.6

Control board diagnostics

1. Press ON/OFF button
into ON.
2. Immediately following, press and hold simultaneously buttons
or
and
for 3 seconds, until display reads P2.
P
3. Press
to enter P2 adjustment. The current setting will appear on
P
the display. If not, repeat process.
4. Press and release the
button on the control panel until the
P
display reads 'P4'. You are now in the diagnostic mode of the control
board.
5. When the display reads 'P4', press and release the
again and the display should read 'E'.
+
6. Use the
and
button on the control board to cycle through
different diagnostic modes available.
7. Once in the selected diagnostic mode of your choice, press and
release the
button to display the diagnostic information.
P
EXAMPLE: to read the flow rate in gallons per minute while the unit is
flowing water, cycle to the '3d' mode and press the
reading of 25 on the display would indicate the heater is reading a flow
rate of 2.5 gallons/minute.
8. Once the information is obtained, press the
return to the diagnostic mode menu and scroll to addition diagnostic
information.
9. Press ON/OFF button to turn OFF the appliance and back ON again to
return heater to normal function.
Diagnostic menu
E
Entry/Exit into sub-modes
0d
Heat exchanger water temperature
1d
Inlet water temperature (°F)
2d
Outlet water temperature (°F)
3d
Water flow (gallons/min)
4d
Bypass control monitor (°F) [0d - 2d]
5d
Fan speed (Hz)
6d
Burner power (%)
7d
Maximum power (kW)
8d
Back flow temperature (°C)
9d
Exhaust temperature (°C)
1F
Most recent error/failure
2F
2nd most recent error
3F
3rd most recent error
4F
4th most recent error
5F
5th most recent error
6F
6th most recent error
7F
7th most recent error
8F
8th most recent error
9F
9th most recent error
10F
10th most recent error
1P*
Appliance type - Cd (Condensing)
Appliance type - nC (Non condensing)
2P*
Appliance power - 175 / 199 (kBTU/hr)
Table 38 * Settings define from factory
RTG 199 ME – 6 720 811 615 (2015/04)
Diagnostic menu
+
3P*
H0
H1
H2
+
button once
Table 38 * Settings define from factory
7.6.1
To see how many hours the appliance has worked, please enter the
"Diagnostic menu" (chapter 7.6);
▶ Select the sub-mode "H0".
▶ Select the sub-mode "H1".
button. A
P
▶ Select the sub-mode "H2".
button again to
P
After checking the sub-modes H0, H1 and H2, introduce the values in
the table below;
Working hours
Number in H0
Number in H1
Number in H2
(H0 + H1 + H2) = Total of hours
Table 39
Example:
Calculation of number of working hours,
Working hours
Number in H0
Number in H1
Number in H2
(H0 + H1 + H2) = Total of hours
Table 40
Temperature range - H (100-140°F)
Temperature range - C (100-184°F)
Numbers of hours - mode 0
Numbers of hours - mode 1
Numbers of hours - mode 2
Working hours
Write the number that shows in the display.
Write the number that shows in the display.
Write the number that shows in the display.
______ (X 100) =
______ (X 10 000) =
5 (X 100) =
0 (X 10 000) =
Maintenance and service
______
_______ +
_______ +
_______
__________
60
60 +
500 +
0
560
41