Maintenance and service
7.5

Program values

This section describes details on programming the appliance. For most
applications the factory default values will provide robust and stable
operation. Only adjust the factory settings if the installation requires
changes as indicated in the appropriate section of this manual.
Program
Description
P1
Maximum Power
P2
Minimum Power
P3
Remote
Controls installed
P4
Access to
Diagnostic Mode
P5
Cascade Mode
P6
Temperature Unit
P7
Gas type selection
P8
Back light
P9
Fan Purge
PH
Cascading type
PC
Primary/Secondary
mode
Table 37 Program values, factory default settings and ranges.
40
Refer to chapter 7.6 Control board diagnostics (page 41) regarding how
to access these P-modes.
Factory Default
MIN
NG: 54,
21
LP: 46
7
7
_0
_0
E
0d
NO
NO
°F
°F
LP or NG
dE
dE
IC
IC
CS
CS
CAUTION: Appliance malfunction!
▶ Misadjusted program values can lead to appliance
malfunction, errors, and service calls.
MAX
NG: 55,
see chapter 4.14, page 32
LP: 49
note: reducing P1 values below maximum will
reduce maximum power of the appliance.
20
see chapter 4.3.8, page 22
6
10f
see chapter 7.6, page 41
CC
contact manufacturer for details
°C
Preset from factory.
Contact manufacturer for details.
On
dE turns back light off after 60 seconds from
last button pushed, ON turns backlight on
Runs secondary fan and primary fan when P9
is selected by depressing the "P" - button
SC
This menu is only available when cascade
mode is selected CC.
Contact manufacturer for details.
Cn
RTG 199 ME – 6 720 811 615 (2015/04)
Comment
Not available
permanently.