Operation instructions
this symptom, clean fixtures or replace with higher flowing ones if
necessary.
Saving water resources:
▶ Make sure you close all the taps after any use. Avoid leaving the taps
dripping. Repair any leaking tap.
▶ Define the temperature you want, in the appliance or with the remote
control. This way you have the precise water flow needed (mixing
cold water to regulate temperature will increase the water flow with
consequent waste of water).
The water heater will not ignite if inlet water temperature exceeds the set
point temperature less 9 °F (5 °C). In this condition, the solar mode
indicator will show on the LCD display. See fig. 51, page 35.
Solar mode activation formula
Temp. inlet > Temp. set - 9 °F
(5 °C)
Table 34
WARNING: Appliance damage!
▶ In applications where inlet water temperature can
exceed 140°F (60°C), a thermostatic or mixing valve
must be installed before the appliance to prevent
water exceeding 140°F (60°C) from entering the
appliance.
Fig. 55
6.5

Operation

▶ When a hot water tap is opened, main burner ignites and LCD
displays indication
.
Fig. 56
36
Example:
104 °F (40 °C) > 112 °F (44 °C) -
9 °F (5 °C)
▶ LCD flashes until selected temperature is reached.
▶ Power bar indicates power percentage in use.
6.6

Reset button

If the LCD shows the error symbol
the heater. Follow instructions below to reset error first.
Record the error code on LCD and consult "Problem solving" chapter
9.1, page 44.
Fig. 57
After following instructions indicated in "Troubleshooting" section,
▶ press reset button firmly in order to return heater to normal
operation.
Fig. 58 Reset button
If the problem persists, contact your installer.
6.7

Program button

Fig. 59 "Program" key
6.7.1
Memorizing selected temperature
+
▶ Press buttons
or
to select desired temperature.
▶ Hold "Program" button for 3 seconds to save temperature.
When LCD stops blinking, temperature is saved in memory.
Using "Program" function
In order to select memorized temperature
▶ Press "Program" key.
LCD shows pre-memorized temperature, which is now the hot water
selected temperature.
6.8

Locked condition

This condition is only valid for appliances with one or more remote
controls installed.
do not shut off power or unplug
6720608920-14. 1 AL
6720608920-15. 1 AL
RTG 199 ME – 6 720 811 615 (2015/04)