Alcove Installation; Stove Installation; Installation When Installed With Blower Kit Ep63 - Napoleon 1600C-1 Installation And Operation Instructions Manual

Listed solid fuel burning space heater
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION
INSTALLED WITH BLOWER
KIT EP63
For reduced clearances installation must comply with
NFPA 211or CAN/CSA-B365.

Alcove installation

Model 1600C-1 may be installed into an alcove having a
depth of not more than 4 feet and a height of at least 7 feet,
when using a listed double wall connector that is rated for a
minimum 12" clearance to combustible material.
The minimum clearances are as shown.
Alcove installation
Walls shall not extend from front of unit when installed
in the alcove configuration.

Stove installation

If the stove is to be installed on a
combustible floor, it must be
p l a c e d
o n
a
a p p r o v e d
non-combustible hearth pad,
t h a t e x t e n d s 8 " ( 2 0 0 m m )
beyond the stove sides and
back, and 18" (455mm) to the
front.
6
WHEN
Listed single wall chimney connector
FROM
UNIT
FROM
PIPE
* A 18 in. Minimum clearance should be maintained
from combustible wall to the chimney connector.
Double walled connectors listed for a minimum
clearance of 12" or less from combustible materials
must be used to achieve the following clearances.
FROM
UNIT
FROM
PIPE
Flue configuration
Type 1
Horizontal
A
16"
B*
10"
C
11"
D
25"
E
...
F
...
Flue configuration
Type 2
Horizontal
A
16"
B
10"
C
11"
D
25"
E
...
F
...
Vertical
16"
16"
11"
25"
18"
18"
Vertical
16"
10"
11"
25"
16"
12"

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents