HARD WIRING CONNECTION
If it is necessary to hard wire this appliance, a qualifi ed electrician may remove the cord connection, and wire
the appliance directly to the house hold wiring.
This appliance must be electrically connected and grounded in accordance with local codes, if hard wired. In
the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the
ANSI/NFPA 70-1996 NATIONAL ELECTRICAL CODE in the United States.
2.5.1
Remove cover plate located beside the power cord to reveal the 7/8" wire hole. Discard cover plate,
screws and insert a box connector into the hole.
2.5.2
Remove the lower back panel from the appliance to expose wiring.
2.5.3
Remove the power cord strain-relief from the side of the appliance and cut the cord where shown
below. This will be the hard wire connection point.
2.5.4
Feed the supply wires through the box connector and the grommet.
2.5.5
Using wire connectors connect the common (white) wires together, then the hot (black) wires, and then
the ground (green) wires.
2.5.6
Ensure the newly connected wires are kept away from the rotating parts and the circuit board, and re-
install the back panel.
NOTE: This appliance must be serviced from the back, leave enough wire so that the appliance can be
removed from the enclosure without disconnecting the power supply wires.
1
Remove 2 screws on cover plate.
Hot Wire
Common Wire
2
Ground Wire
Power Cord
Cut
3
Box
Connector
4
Final Connection
11