Napoleon EF34H Installation And Operation Instructions For

Electric fireplace heater

Advertisement

1
INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA C2.22 No46 / UL1278 CSA STANDARD.
INSTALLATION AND OPERATION INSTRUCTIONS FOR
ELECTRIC FIREPLACE HEATER
EF34H
MODELS
EF36H
WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY,
AN ELECTRICAL SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
R-2000
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031
www.napoleonfireplaces.com • ask@napoleon.on.ca
W415-0405 / B / 03.25.04

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon EF34H

  • Page 1: For Your Safety

    DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. R-2000 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www.napoleonfireplaces.com • ask@napoleon.on.ca W415-0405 / B / 03.25.04...
  • Page 2: Table Of Contents

    TABLE of CONTENTS PG 2-4 INTRODUCTION ELECTRICAL CONNECTION Warranty 10-11 REPLACEMENTS Important Instructions Ordering Replacement Parts Locating Your Fireplace Replacement Parts Dimensions Accessories OPERATION TROUBLE SHOOTING GUIDE Remote Control Flame Effect SERVICE HISTORY Maintenance FINISHING Mantel Installation Clearance to Combustibles Framing and Finishing Hearth Cold Climate Installation...
  • Page 3: Warranty

    Napoleon will not be responsible for installation, labour or any other expenses related to the reinstallation of a warranted part and such expenses are not covered by this warranty. Notwithstanding any provisions contained in this Limited Warranty, NAPOLEON’S responsibility under this warranty is defined as above and it shall not in any event extend to any incidental, consequential or indirect damages.
  • Page 4: Important Instructions

    IMPORTANT INSTRUCTIONS LOCATING YOUR ELECTRIC FIREPLACE 1. READ ALL INSTRUCTIONS BEFORE USING THIS APPLI- Your new fireplace may be installed into an existing ma- ANCE. THIS APPLIANCE IS HOT WHEN USED. sonry or zero clearance fireplace. It may also be installed using a prefabricated cabinet available from your dealer or 2.
  • Page 5: Operation

    OPERATION REMOTE CONTROL FLAME EFFECT This fireplace is supplied with a radio frequency remote The flame generator has a random modulating control control. This remote will function up to 20 feet away from which causes the flame effect to speed up and slow down the fireplace.
  • Page 6 FINISHING MANTEL FRAMING AND FINISHING The minimum distance from the top of the unit that the mantel can be installed is 0", at any depth. Nailing When using paint or lacquer to finish the When using paint or lacquer to finish the When using paint or lacquer to finish the When using paint or lacquer to finish the When using paint or lacquer to finish the...
  • Page 7 EF34 EF36 Corner Installation Corner Installation Top View Top View Front View Front View Note: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the fireplace body, it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall/sheetrock), as you would finish any other outside wall of a home.
  • Page 8 3. The bottom end of log #2 is pressed against the inner HEARTH right side of the chamber. The underside branch of log #2 fits under the top end of log #1. A A A A A hearth is NOT necessary hearth is NOT necessary hearth is NOT necessary hearth is NOT necessary but is recommended for aes-...
  • Page 9: Electrical Connection

    ELECTRICAL CONNECTION This fireplace requires a 15 amp, 120 volt and 60 hz ELECTRICAL DIAGRAM LEGEND circuit that is grounded to the electrical socket. The fire- place should be on its own circuit. If there are other 1. 1. 1. 1. 1. Power (Rocker Switch) Power (Rocker Switch) Power (Rocker Switch)
  • Page 10: Replacements

    ERIAL UMBER OF FIREPLACE availability of replacement parts. Normally all parts can be 2. I NSTALLATION DATE OF FIREPLACE ordered through your Napoleon dealer or distributor. 3. P UMBER When ordering replacement parts always give the follow- 4. D ESCRIPTION OF PART ing information: 5.
  • Page 11 W415-0405 / B / 03.25.04...
  • Page 12: Trouble Shooting Guide

    TROUBLE SHOOTING GUIDE SYMPTOM PROBLEM TEST SOLUTION No Flame Light but - Light bulbs have burned out. - Remove access panel and change everything else is light bulbs. working properly. Flame light, but no - Flame generator motor has burned out. - Consult your local dealer.

This manual is also suitable for:

Ef36h