OPTIONAL BLOWER INSTALLATION

THIS BLOWER IS NOT SUITABLE FOR THE 4 SIDED ISLAND INSTALLATION.
in accordance with local codes. In the absence of local
codes, use the current CSA C22.1 C
in Canada or the ANSI/NFPA 70
United States.
Remove
the
blower from its
mounting bracket
and attach to the
bracket supplied
with the fireplace.
This bracket is
found secured on
the mounting stud
located at the bot-
tom of the vent
side wall.
FIGURE 42
The blower bracket contains two holes that allow the blower
to be positioned away from the intended gas supply hole.
Position the vibration reducing pad, centred, onto the
threaded stud, piercing a hole into the pad. The blower
must be able to be positioned entirely onto the pad.
Tilt the blower onto its side and slide it past the controls.
Position the blower under the clip and onto the stud. Se-
cure with a wing nut.
FIGURE 43
W415-0320 / D / 01.06.07
ANADIAN ELECTRICAL CODE
in the
NATIONAL ELECTRICAL CODE
FIGURE 40
FIGURE 41
THERMODISC WIRES TO BLOWER
THERMODISC BRACKET
Remove the thermodisc bracket from the top of the firebox.
Remove the thermodisc from the bracket supplied in the
blower kit and install the thermodisc into the fireplace
bracket. Then replace the bracket in the location it was
removed.
Connect the two ends of the unattached wires by the bracket
to the thermodisc.
Connect the opposite ends of the wires to the red and
black leads of the blower harness.
The wire harness provided in this kit is a universal har-
ness. When installed, ensure that any excess wire is
contained, preventing it from making contact with mov-
ing or hot objects.
Drywall dust will penetrate into the blower bearings,
causing irreparable damage. Care must be taken to
prevent drywall dust from coming into contact with the
blower or its compartment. Any damage resulting from
this condition is not covered by the warranty policy.
Because the blower is thermally activated, when turned
on, it will automatically start approximately 10 minutes
after lighting the fireplace and will run for approximately
30 - 45 minutes after the fireplace has been turned off.
Use of the fan increases the output of heat.