Napoleon BGNV42N Installation And Operation Instructions Manual

Millivolt system vented natural and propane gas fireplace

Advertisement

Quick Links

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.22, AND ANSI Z21.50 RESPECTIVELY FOR VENTED GAS FIREPLACES.
WARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapours and liquids in the vicinity of
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
Installation and service must be performed by a qualified installer, service agency or
the gas supplier.
R-2000
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031
MILLIVOLT SYSTEM
INSTALLATION AND OPERATION INSTRUCTIONS FOR
VENTED GAS FIREPLACE
NATURAL GAS MODEL
PROPANE GAS MODEL
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS
FOR YOUR SAFETY
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
www.napoleonfireplaces.com • ask@napoleon.on.ca
• Immediately call your gas supplier from
a neighbour's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
1
W415-0377 / 03.04.03

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon BGNV42N

  • Page 1 INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.22, AND ANSI Z21.50 RESPECTIVELY FOR VENTED GAS FIREPLACES. INSTALLATION AND OPERATION INSTRUCTIONS FOR NATURAL GAS MODEL PROPANE GAS MODEL CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 2: Table Of Contents

    TABLE of CONTENTS PG 2-4 INTRODUCTION Warranty General Instructions General Information Care of Glass & Plated Parts 5 VENTING Vent Safety Switch Hi Limit Switch Venting Action Check 6-7 INSTALLATION Gas Installation Framing Nailing Tab Installation Mantle Clearances 8-9 FINISHING Louvre Bracket Installation Door Removal &...
  • Page 3: Warranty

    NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station.
  • Page 4: General Instructions

    GENERAL INSTRUCTIONS THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to re- gion and it is important to know the specifics that apply to your area, for example: in Massachusetts State: •...
  • Page 5: Venting

    This is a vented appliance and must be connected to a chimney in accordance with the current installation codes. In absence of local codes, install to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes. This model can be common-vented. A minimum six inch diameter (6"ø) B-vent or class A vent is required.
  • Page 6: Installation

    GAS INSTALLATION Proceed once the vent installation is complete. 1. Move the fireplace into position and secure using the nailing tabs and/or secure to the floor through the 1/4"ø holes located at either end of the base. 2. Route a 3/8" N.P.T. black iron gas line, 1/2" type-L cop- per tubing or equivalent to the fireplace.
  • Page 7: Nailing Tab Installation

    NAILING TAB INSTALLATION 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws supplied. Secure through the centre of the top and bottom slots in the nailing tab and then through the existing holes in the corner posts.
  • Page 8: Finishing

    LOUVRE BRACKET INSTALLATION FIGURE 14 1. Align the holes in the louvre brackets with the pre-drilled holes in the firebox, as shown. 2. Secure louvre brackets in place using screws. DOOR INSTALLATION The upper louvres must be removed to allow the door to be removed.
  • Page 9: Log Placement

    LOG PLACEMENT PHAZER logs and glowing embers, exclusive to Napo- leon Fireplaces, provide a unique and realistic glowing ef- fect that is different in every installation. Take the time to carefully position the glowing embers for a maximum glow- ing effect. Log colours may vary. During the initial use of the fireplace, the colours will become more uniform as colour pigments burn in during the heat activated curing process.
  • Page 10: Optional Blower Installation

    OPTIONAL BLOWER INSTALLATION INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be electrically connected and grounded in accord- ance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE ANSI/NFPA 70 NATIONAL ELECTRICAL CODE FIGURE 20 The three slots allow ease...
  • Page 11: Optional Fan Installation

    OPTIONAL FAN INSTALLATION ELECTRICAL INSTALLATION TO BE DONE BY A QUALI- FIED INSTALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE United States.
  • Page 12: Operation / Maintenance

    OPERATION / MAINTENANCE OPERATING INSTRUCTIONS When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condi- tion caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again.
  • Page 13: Maintenance

    Turn off the gas and electrical power before servicing the fireplace. CAUTION: Label all wires prior to disconnection when serv- icing controls. Wiring errors can cause improper and dan- gerous operation. Verify proper operation after servicing. This fireplace and its venting system should be inspected before use and at least annually by a qualified service per- son.
  • Page 14: Replacements

    Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Napoleon dealer or distribu- tor. When ordering replacement parts always give the follow- ing information: , , , , , REPLACEMENT PARTS PART NO.
  • Page 15: Trouble Shooting Guide

    TROUBLE SHOOTING GUIDE EFORE ATTEMPTING TO TROUBLESHOOT PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED SYMPTOM PROBLEM Main burner goes Pilot flame is not large out; pilot stays on. enough or not engulfing the thermopile Thermopile shorting Remote wall switch wire is...
  • Page 16 SYMPTOM PROBLEM Pilot goes Gas piping is undersized. while standing; Main burner is in 'OFF' position. Flames are con- Unit is over-fired or under- sistently too large fired. small. Carboning occurs. Carbon is being Air shutter has become deposited blocked glass, logs or com- Flame is impinging on the bustion chamber...

This manual is also suitable for:

Bgnv42p