OPTIONAL FAN INSTALLATION

ELECTRICAL INSTALLATION TO BE DONE BY A QUALI-
FIED INSTALLER and must be connected and grounded
in accordance with local codes. In the absence of local
codes, use the current CSA C22.1
in Canada or the ANSI/NFPA 70
the United States.
FIGURE 26
The wire harness provided in this kit is a universal har-
ness. When installed, ensure that any excess wire is con-
tained, preventing it from making contact with moving or
hot objects.
Position the vibration reducing pad into the clip and onto
the threaded stud at the other end, piercing a hole into the
pad. The fan assembly must be able to be positioned
entirely onto the pad.
THERMOSTATIC SENSOR CONTROL
This optional kit is meant to be used only in conjunction
with the GD65 Fan Kit, shown above, which may be or-
dered from your Wolf Steel / Napoleon dealer.
With the thermostatic sensor option, the fan, when turned
on, becomes thermally activated, and will automatically run
approximately 10 minutes after the fireplace has been lit
and for approximately 30-45 minutes after the fireplace has
been turned off.
Use of the fan increases the output of heat.
Unplug the power cord from the receptacle. Connect all
wires as shown.
CANADIAN ELECTRICAL CODE
in
NATIONAL ELECTRICAL CODE
FIGURE 28
OPTIONAL THERMOSTATIC
JUNCTION BOX
OPEN ENDED
SLOTS
Slide the fan assembly past the controls and and into the
clip. Secure using the lock washer and nut provided.
Plug the harness cord into the receptacle.
Attach and secure the sensor assembly bracket to the se-
curing stud located next to the receptacle/junction box at
the bottom left of the unit using the lock washer and wing
nut. Ensure that the thermodisc touches the firebox wall.
Plug the power cord back into the receptacle.
When installed, ensure that any excess wire is contained,
preventing it from making contact with moving or hot ob-
jects.
THERMODISC
SENSOR ASSEMBLY
RECEPTACLE /
JUNCTION BOX
FIGURE 27
SENSOR
RECEPTACLE /
VARIABLE SPEED/
PIEZO IGNITOR
BRACKET
FIGURE 29
BRACKET