BGD36CF
PERISCOPE TERMINATION

For optimum performance, it is recommended that all hori-

zontal runs have a 1 inch rise per foot.

When terminating vertically, the vertical rise is a minimum 36 inches
and a maximum 40 feet from the centre of the fi replace fl ue outlet.
Use the GD201 periscope kit to locate the air termination
above grade. The periscope must be installed so that when
fi nal grading is completed, the bottom air slot is located a mini-
mum of 12 inches above grade. The maximum allowable vent
length depends on the model of fi replace, as illustrated.

FIGURE 15

TOP EXIT INSTALLATION
BGD42CF
PERISCOPE TERMINATION
Use the GD401 periscope kit to locate the air termination
above grade. The periscope must be installed so that when
fi nal grading is completed, the bottom air slot is located a
minimum of 12 inches above grade.

SPECIAL VENT INSTALLATIONS

FIGURE 16
REAR EXIT INSTALLATION
FIGURE 17
CORNER TERMINATION
The maximum vent length for a corner installation is 20 inches
of horizontal run, in addition to the 45° offset. In this case zero
rise is acceptable when using rigid. See FIGURE 18. Flexible
venting must maintain a 6" rise. See FIGURE 19.
FIGURE 18
9
FIGURE 19