venting requirements
EN
2.2
special vent installations
2.2.1 periscope termination
Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when
fi nal grading is completed, the bottom air slot is located a minimum 12" (305mm) above grade. The maximum
allowable vent length (including both rise and run) is 10' (3m) for a fi replace and 8' (2m) for a stove. An insulation
sleeve is illustrated in the top vent image below, use only when supplied with the appliance.
(The insulation sleeve is not required with a stove appliance)
24" (61cm)
MINIMUM
12"
MINIMUM
30"
MINIMUM
2.2.2 corner termination
The maximum vent length for a corner installation is 20" (50.8cm) of horizontal run, in addition to the 45° offset. In
XIMUM 10FT VENT LENGTH
this case, zero rise is acceptable. See illustrations below. It is recommended to maintain a 6" (152mm) rise.
LLATION
REAR EXIT INSTALLATION
12
W415-2355 / A / 12.09.20
12"
MINIMUM
REAR VENT
6" (152mm)
RISE MINIMUM
6" (152mm)
RISE MINIMUM
12" (30.5cm)
MINIMUM
TO GRADE
24" (61cm)
MINIMUM
30"
MINIMUM
TOP EXIT INSTALLATION
20" (50.8cm)
MAXIMUM
20" (50.8cm)
MAXIMUM
12" (30.5cm)
MINIMUM
TO GRADE
12"
MINIMUM
30"
MINIMUM
TOP VENT
8.1
MAXIMUM 10FT VENT LENGTH
REAR EXIT INSTAL
6
R