Unit Dimensions; Venting; Venting Lengths - Napoleon BGD36CFNTR Installation And Operating Instructions Manual

Table of Contents

Advertisement

BGD36CF
FIGURE 1
38
1
/
"
2
34"
FIGURE 3
4" DIA.
7" DIA.
T
THE BGD36CF USES: 4" EXHAUST / 7" AIR INTAKE VENT PIPE
THE BGD42CF USES: 5" EXHAUST / 8" AIR INTAKE VENT PIPE
MODEL BGD36CF MAY BE VENTED EITHER AS A TOP VENT OR A REAR VENT.
For safe and proper operation of the fi replace follow the venting instruction exactly.
Deviation from the minimum vertical vent length can create diffi culty in burner start-up and/or carboning.
Provide a means for visually checking the vent connection to the fi replace after the fi replace is installed.
Vent lengths that pass through unheated spaces (attics, garages, crawl spaces) should be insulated with the insula-
tion wrapped in a protective sleeve to minimize condensation.

VENTING LENGTHS

Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp
or American Metal Amerivent venting components. Minimum
and maximum vent lengths, for both horizontal and vertical
installations, and air terminal locations for either system are
set out in this manual and must be adhered to. For Simpson
Dura-Vent, Selkirk Direct Temp and American Metal Ameriv-
ent, follow the installation procedure provided with the venting
components.
All outer pipe joints of these venting systems must be sealed
using Red RTV High Temperature Sealant.
A starter adaptor must be used with the following vent systems
and may be purchased from the corresponding supplier:
PART
4"/7"
Duravent
W175-0053
Amerivent
4DSC-N2
Direct Temp
4DT-AAN
For vent systems that provide seals on the inner exhaust fl ue,
only the outer air intake joints must be sealed using a red high
temperature silicone (RTV). This same sealant may be used
on both the inner exhaust and outer intake vent pipe joints of
all other approved vent systems except for the exhaust vent
pipe connection to the fi replace fl ue collar which must be
sealed using the black high temperature sealant Mill Pac.

UNIT DIMENSIONS

FIGURE 2
24
5
1
/
"
2
3"
ELECTRICAL INLET
LEFT SIDE
27"
17"
15"
10"
40"

VENTING

REFER TO THE SECTION APPLICABLE TO YOUR INSTALLATION.
5"/8"
SUPPLIER
W175-0170
Wolf Steel
5DSC-N
American Metal
5DT-AA
Selkirk
FIGURE 4
41 1 /2"
33"
1
/
"
4
GAS
37"
INLET
5" DIA.
8" DIA.
BGD36CF
When using Wolf Steel venting components, use only
approved Wolf Steel rigid / fl exible components with the
following termination kits: WALL TERMINAL KIT GD222,
or 1/12 to 7/12 PITCH ROOF TERMINAL KIT GD110,
8/12 to 12/12 ROOF TERMINAL KIT GD111, FLAT ROOF
TERMINAL KIT GD112 or PERISCOPE KIT GD201 (for
wall penetration below grade). With fl exible venting, in
conjunction with the various terminations, use either the
5 FOOT VENT KIT GD220 or the 10 FOOT VENT KIT
GD330.
BGD42CF
When using Wolf Steel venting components, use only ap-
proved Wolf Steel fl exible components with the following
termination kits: WALL TERMINAL KIT GD422, or 1/12 to
7/12 PITCH ROOF TERMINAL KIT GD410, 8/12 to 12/12
ROOF TERMINAL KIT GD411, FLAT ROOF TERMINAL
KIT GD412 or PERISCOPE KIT GD401 (for wall penetra-
tion below grade). With fl exible venting, in conjunction with
the various terminations, use either the 5 FOOT VENT KIT
GD420 or the 10 FOOT VENT KIT GD430.
Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp
or American Metal Amerivent venting systems must
not be combined. Wolf Steel rigid and fl exible venting
systems must not be combined.
BGD42CF
FIGURE 5
5 1 /2"
3"
ELECTRICAL INLET
LEFT SIDE
FIGURE 6
20
/
"
1
2
23"
25"
46"
W415-0566 / E / 09.28.07
5
35
1/2"
GAS
INLET