Factory
Register Range
Default
S18
0–255
000
S25
0–255
005
S30
0–90
000
S36
0–7
S37
0–19
0
S38
0–23
S48
7 or 128
7
MT5634ZLX, MT5634ZLXI, MT5634ZLX/FE User Guide
Chapter 4 – AT Commands, S-Registers, and Result Codes
Description
18
115200 bps
Sets the length of time, in seconds, that the modem conducts a test
(commanded by "AT&Tn") before returning to command mode. If this
register value is zero, the test automatically terminates, the test progress
must be ended by issuing "AT&T0" or "ATH" commands.
Sets the length of time, in hundredths of a second, which the modem
ignores before hanging up.
Controls the inactivity timer, which sets the length of time, in minutes, that
the modem counts when there is no data flow in or out of the DTE serial
port. A connection is disengaged when the counter reaches the preset
value. Setting to S30 =0 disables the inactivity timer.
Specifies the action to take in the event of a negotiation failure when error
control is selected. (See S48)
Sets the desired DCE speed (line speed).
0
Attempt to connect at the last "AT" speed
3
Attempt to make a 300 bps connection
5
Attempt to make a 1200 bps connection
6
Attempt to make a 2400 bps connection
7
Attempt to make a 4800 bps connection
8
Attempt to make a 7200 bps connection
9
Attempt to make a 9600 bps connection
10
Attempt to make a 12000 bps connection
11
Attempt to make a 14400 bps connection
12
Attempt to make a 16800 bps connection
13
Attempt to make a 19200 bps connection
14
Attempt to make a 21600 bps connection
15
Attempt to make a 24000 bps connection
16
Attempt to make a 26400 bps connection
17
Attempt to make a 28800 bps connection
18
Attempt to make a 31200 bps connection
19
Attempt to make a 33600 bps connection
Sets "downstream" data rate where K56 provides rates of
32,000 to 56,000 in 2,000 bps increments, V.90 provides rates of
28,000 to 56,000 bps in increments of 1,333 bps.
0 = V.90 disabled
1 = V.90 autorate
2 = 28,000 bps
3 = 29,333 bps
4 = 30,666 bps
5 = 32,000 bps
6 = 33,333 bps
7 = 34,666 bps
8 = 36,000 bps
9 = 37,333 bps
10 = 38,666 bps
11 = 40,000 bps
12 = 41,333 bps
13 = 42,666 bps
14 = 44,000 bps
15 = 45,333 bps
16 = 46,666 bps
17 = 48,000 bps
18 = 49,333 bps
19 = 50,666 bps
20 = 52,000 bps
21 = 53,333 bps
22 = 54,666 bps
23 = 56,000 bps
Enables (7) or disables (128) LAPM negotiation. The following table lists
K56 rates
2 = 32,000 bps
3 = 34,000 bps
4 = 36,000 bps
5 = 38,000 bps
6 = 40,000 bps
7 = 42,000 bps
8 = 44,000 bps
9 = 46,000 bps
10 = 48,000 bps
11 = 50,000 bps
12 = 52,000 bps
13 = 54,000 bps
14 = 56,000 bps
Note:Upstream V.90 data rates are
4800 to 33,600 bps in 2400 bps
increments.