COMMAND:
#A n
VALUES:
n = 0 thru 3
DEFAULT:
#A0
DESCRIPTION:
#A0 selects initial handshake at 33,600 to 31,200 to 28,800
#A1 selects initial handshake at 33,600 bps only.
#A2 selects initial handshake at 33,600 to 31,200 to 28,800
#A3 selects initial handshake at 2400 to 1200 to 300 bps.
COMMAND:
&B n
VALUES:
n = 0 or 1
DEFAULT:
&B0
DESCRIPTION:
&B0 selects normal transmit buffer size.
&B1 selects reduced transmit buffer size.
COMMAND:
&BS n
VALUES:
n = 0 or 1
DEFAULT:
&BS1
DESCRIPTION:
&BS0 selects maximum transmit block size of 64 characters.
&BS1 selects maximum transmit block size of 256
COMMAND:
B n
VALUES:
n = 0 or 1
DEFAULT:
B0
DESCRIPTION:
B0 selects V.21 for 300 bps operation.
B1 selects for 300 bps operation.
(Not used in International Models.)
COMMAND:
$BA n
VALUES:
n = 0 or 1
DEFAULT:
$BA0
DESCRIPTION:
$BA0 selects speed conversion on.
$BA1 selects speed conversion off.
Chapter 4 - AT Commands, S-Registers and Result Codes
to 24000 to 21,600 to 19,200 to 16,800 to 14,400 to12,000
to9600 to 4800 to 2400 to 1200 to 300 bps.
to 24000 to 21600 to 19,200 to 16,800 19,200 to 14,400
to 9600 to 4800 bps.
characters (MNP mode)/128 characters (LAP-M mode).