Fujitsu Primergy RX100 S3 User Manual page 280

Hide thumbs Also See for Primergy RX100 S3:
Table of Contents

Advertisement

C Remote Control Function and Console Redirection
■ Connection
1
Connect the serial port connector 1 to the management terminal using an RS-
232C cross cable.
2
Establish connection using the terminal software.
■ Operation on the Server
Perform the following operation in the terminal software on the management terminal.
1
Establish connection using the terminal software and press the [Enter] key.
The following message appears.
Login>
2
Enter the following command.
Remote [Enter]
The following message appears.
Password>
3
Enter the following command.
Remote [Enter]
The following menu appears.
*******************************************
Welcome to System RX100 S3
BMC FW: *.**
State: Off (na = Currently not available)
*******************************************
The "State" line in the message will show either of the following.
ON
OFF
280
SDRR: *.**
REMOTE MAINTENANCE MENU
(1) Immediate Power Down
(2) Immediate Reset
(3) Graceful Power Down
(4) Power Cycle
(5) Power On
(6) View System Eventlog (SEL)
Enter selection or (0) to quit:
table: Messages in the Main Menu Window
Message
The server is turned on.
The server is turned off.
Status