A Special Note For Network Interface Connections - AMX MVP-5100 Operation/Reference Manual

Hide thumbs Also See for MVP-5100:
Table of Contents

Advertisement

8. Select the panel's Kit file from the Files section.
9. Enter the Device value associated with the panel and the System number associated with the Master
(listed in the OnLine Tree tab of the Workspace window). The Port field is greyed-out.
10. Click the Reboot Device checkbox. This causes the touch panel to reboot after the firmware update
process is complete.
11. Click Send to begin the transfer. The file transfer progress is indicated on the bottom-right of the
dialog (B in FIG. 69).
12. After the file transfer is complete, the panel will automatically reboot. As the panel is rebooting,
temporarily unplug the USB connector on the panel until the panel has completely restarted.
13. Once the first panel page has been displayed, reconnect the USB connector to the panel.
14. Right-click the associated System number and select Refresh System. This causes a refresh of all
project systems, establishes a new connection to the Master, and populates the System list with
devices on your particular system.
15. Confirm that the panel has been properly updated to the correct firmware version.
Verify you have downloaded the latest firmware file from www.amx.com and then
save the Kit file to your computer.

A Special Note for Network Interface Connections

Due to any USB connection to your PC being made through a Network Interface Connection (NIC),
Windows will automatically make any new NIC connection the Primary connection. If this happens, the
USB address of 12.0.0.x will show up across the PC's network switches as the PC's source address. In
some cases, network administrators will notice the NIC connection and reconfigure any PC that has
connected to the MVP-5100. Business, college, and government installations are the type of installations
that would be most affected, and most home installations would not be affected.
To prevent the NIC connection from becoming the primary connection:
1. From the Windows Start menu, select Settings > Control Panel to open the Control Panel window.
2. In the Control Panel window, click on the Network Connections icon to open the Network
Connections window (FIG. 70)
FIG. 70
Network Connections window
MVP-5100/5150 5.2" Modero Viewpoint Touch Panels
Upgrading Firmware
93