Ac. Generator Removal; Right Crankcase Cover Bearing - Sym RV 250i Service Manual

Table of Contents

Advertisement

To this chapter contents
10. AC. Generator / Start Clutch

AC. Generator Removal

3 screws
Remove 2 mounting screws from pulse generator.
Remove 3 screws from right crankcase cover and
then remove generator coil set.
Pulse generator screws
Cir clip

Right Crankcase Cover Bearing

Rotate the bearing with finger to check if the
bearing rotation is in smooth and silent.
Check if the bearing outer parts are closed and
fixed. Replace it if necessary.
Remove the bearing 6201with inner bearing puller.
Special tool:
Inner bearing puller
SYM-6204022
Inner bearing puller
Install the bearing 6201 bearing with special tool.
Special tool:
Right crankcase cover bearing 6201 presser
SYM-9614000-HMA RB1 6201
Inner bearing presser
10-4