External Extension H - Viessmann VITOLADENS333-F Service Instructions Manual

Type vp3s, 12.9/19.3 kw, 16.1/23.5 kw oil fired compact condensing boiler, for the combustion of low sulphur fuel oil din 51603-el-1
Table of Contents

Advertisement

Function description
Extensions for external connections . . .

External extension H2

The external extension is connected
to the boiler control unit via the KM
BUS. The following functions can be
controlled or processed simulta-
neously via the extension:
A
ON/OFF switch (on site)
sK
DHW circulation pump (only for
weather-compensated opera-
tion)
Power supply
86
(cont.)
aVD
External blocking
(terminals 2 - 3)
External demand
(terminals 1 - 2)
External heating program
changeover (terminals 1 - 2)
(only for weather-compen-
sated operation)
The allocation of the function
"External heating program
changeover" is set via coding
address "91".
aVG KM BUS