Care and Maintenance
12
Checking/adjusting the air pressure
.04
Fig. 12 - 04
12
Cleaning the air filter of the air-filter/lubricator
.05
12 - 3
8
10
6
100
150
4
50
200
2
230
0
0
1
8
10
6
100
150
4
50
200
2
230
0
0
2
1
Fig. 12 - 05
2
12
14
16
To drain water bowl 1:
12
14
16
Cleaning filter 2:
Before operating the machine, always
check the air pressure on gauge1.
Gauge 1 must show a pressure of 6 bar.
If necessary adjust to this reading.
To do so, pull knob 2 upwards and turn it
so that the gauge shows a pressure of 6
bar.
Switch the machine off!
Disconnect the air hose at the
air-filter/lubricator.
Water bowl 1 drains itself automatically
when the compressed-air hose is discon-
nected from the air-filter/lubricator.
Unscrew water bowl 1.
Take out filter 2.
Clean filter 2 with compressed air or iso-
propyl alcohol (part No. 95-665 735-91).
Screw in filter 2 and screw on water
bowl 1.