Adjustment
13

Needle thread tension release

.05.24
13 - 26
Requirement
When the hand lever 1 is raised, the tension discs should be at least 0.5 mm apart.
1
Fig. 13 - 24
Adjust tension release clip 2 (screw 3) according to the requirement.
Lower the presser foot onto the needle plate. The tension must now be fully effective.
0,5 mm
3
2