479536
4.4
Gas Valve Assembly Replacement
Flame Detect Thermostat
• Disconnect the power and gas supply.
• Remove the drum assembly.
• Disconnect the wiring harnesses from the gas coils.
• Unscrew the bracket for the supply pipe from the back panel.
• Unscrew the valve bracket and feed the entire gas burner and valve assembly out through the
opening in the front cabinet bracket.
• Remove the two screws securing the burner to the valve bracket.
• Remove the two screws securing the valve to the valve bracket.
• Remove the two screws securing the coils to the valve.
Reassembly is the reverse procedure.
4.4.1
Flame Detect Thermostat Replacement
• Disconnect the power supply.
• Remove the drum assembly.
• Unscrew and remove the burner.
• Disconnect the wires to the flame thermostat.
• Undo the 2 screws securing the combustion chamber.
• Turn the chamber to the left; undo the screws holding the thermostat and remove.
Reassembly is the reverse procedure.
Burner
Gas Valve
26