479536
Replace the wires from the old timer to the new timer wire for wire. If you think you have made a
mistake fitting the wires, see the diagram below for the wiring locations on the timer.
Reassembly is the reverse procedure.
4.1.2
Selector Switch Replacement
• Open the console.
• Undo the selector switch screws and remove switch assembly.
• Unclip the cover from the selector switch.
• Swap the wires from the old switch to the new switch, wire for wire.
• If you think you may have made a mistake fitting the wires, check against the diagram below.
Reassembly is the reverse procedure.