Periodic Maintenance - Exmark LAZER Z Operator's Manual

Air-cooled models
Hide thumbs Also See for LAZER Z:
Table of Contents

Advertisement

For Exmark Mower Parts Call 606-678-9623 or 606-561-4983

4.1 PERIODIC MAINTENANCE

4.1.1
4.1.2
Check engine oil level:
Service Interval: Daily
a) Stop engine and wait for all moving parts to stop. Make sure unit is on a
level surface.
b) Check with engine cold.
c) Clean area around dipstick. Remove dipstick and wipe oil off. Reinsert the
dipstick and push it all the way down into the tube. Remove the dipstick and
read the oil level.
d) If the oil level is low, wipe off the area around the oil fill cap, remove cap and
fill to the "FULL" mark on the dipstick. Use oil as specified in Engine
Owner's Manual. DO NOT overfill.
IMPORTANT: DO NOT operate the engine with the oil level below the
"LOW" (or "ADD") mark on the dipstick, or over the "FULL" mark.
Check battery charge:
Service Interval: Monthly
Allowing batteries to stand for an extended period of time without recharging
them will result in reduced performance and service life. To preserve optimum
battery performance and life, recharge batteries in storage when the open
circuit voltage drops to 12.4 volts.
Note: To prevent damage due to freezing, battery should be fully charged
before putting away for winter storage.
a) Check the voltage of the battery with a digital voltmeter. Locate the voltage
reading of the battery in the table below and charge the battery for the
recommended time interval to bring the charge up to a full charge of 12.6 volts
or greater.
IMPORTANT: Make sure the negative battery cables are disconnected and the
battery charger used for charging the battery has an output of 16
volts and 7 amps or less to avoid damaging the battery (see
chart below for recommended charger settings).
Voltage
Percent
Reading
Charge
12.6 or greater
100%
12.4 – 12.6
75 – 100%
12.2 – 12.4
50 – 75%
12.0 – 12.2
25 – 50%
11.7 – 12.0
0 – 25%
11.7 or less
0%
IMPORTANT: For Kohler EFI units: Unplug the harness from the ECU
before performing any welding on the equipment.
www.mymowerparts.com
Maximum
Charger Settings
16 volts/7 amps
16 volts/7 amps
16 volts/7 amps
14.4 volts/4 amps
14.4 volts/4 amps
14.4 volts/2 amps
23
Charging Interval
No Charging Required
30 Minutes
1 Hour
2 Hours
3 Hours
6 Hours or More