seTup & TesTInG
Ventilation system settings Table (continued)
system setting
Description
Number of Bedrooms
Selects the number of bedrooms to be used for the ASHRAE
calculation . (Only available if Fresh Air Setup is set to ASHRAE .)
Number of Occupants
Selects the number of occupants to be used for the ASHRAE
calculation . (Only available if Fresh Air Setup is set to ASHRAE .)
Home Size
Selects the home size to be used for the ASHRAE calculation .
(Only available if Fresh Air Setup is set to ASHRAE .)
Fresh Air CFM
Selects the ventilation CFM to be used for the ASHRAE
calculation . (Only available if Fresh Air Setup is set to ASHRAE .)
Select Climate
Selects the climate to be used for the ASHRAE calculation .
(Only available if Fresh Air Setup is set to ASHRAE .) To
determine what region you are in, refer to the map below.
ASHRAE Cycle Time
Displays the Fresh Air Time calculated by the ASHRAE
standard . (Only displayed if Fresh Air Setup is set to ASHRAE .)
Fresh Air Service
The period for displaying the "Fresh Air Service Reminder"
Reminder
message .
note: In ASHRAE set-up temperature and humidity limits are disabled .
ClIMaTe Map FoR asHRae FResH aIR seTup
VeRy ColD
16
Factory default setting (bold)
The system test menu is used to test a system after installation . The outputs of the Home Comfort Control can be
and setting range
manually activated to test their function . The instructions below show how to enter the test mode and turn outputs
3 bedrooms
on and off .
1 to 6 Bedrooms
4 occupants
HoW To enTeR THe sysTeM TesT Menu:
1 to 10 Occupants
press [MoDe] to set system to off .
2500 sQ FT
press and hold [Fan] and [MoDe] for three seconds
1000 to 5000 SQ FT
to enter system test mode .
60 CFM
30 to 200 CFM
The first screen of the installer test displays the
equipment configuration .
normal
Very Hot/Humid
press [neXT] to enter the first installation test or
Very Cold
[CanCel] to exit.
Minutes/Hour
off
1 to 12 months or "Off" to disable
TEMPERATURE
Each equipment test will begin with the selection of turning on the output or stage as shown below .
press
press [neXT] to accept the selection and proceed to the next step.
If yes is selected, the Home Comfort Control will test the corresponding output. If no is selected, the Home
Comfort Control will proceed to the next step.
VeRy HoT/HuMID
TEMPERATURE
EQUIPMENT TEST
SELECTION
seTup & TesTInG

sysTeM TesT Menu

or
to change the selection .
sysTeM TesT sTeps
Heating equipment test
Cooling equipment test
Fan equipment test
Humidification equipment test
Dehumidification equipment test
Ventilation equipment test
Air Cleaning equipment test
HUMIDITY
OUTDOOR
TEMPERATURE
EQUIPMENT
CONFIGURATION
HUMIDITY
OUTDOOR
TEMPERATURE
TEST TO BE RUN
17