SETUp & TESTINg

SYSTEM TEST MENU

The system test menu is used to test a system after installation . The outputs of the thermostat or humidistat can be
manually activated to test their function. The instructions below show how to enter the test mode and turn outputs
on and off .
HOw TO ENTER THE SYSTEM TEST MENU:
press [MODE] to set system to off .
press and hold [fAN] and [MODE] for three seconds
to enter system test mode . Note: Buttons will not be
shown in humidistat mode . Press in the same area that
the button would be displayed .
The screen of the first test step is displayed:
TEST NUMBER
MODEL
FLASHES
(SW1 SETTING)
IF 24VAC
IS NOT
PRESENT
OUTPUT
STATE
STAGE
Test Number
Thermostat System Test
60
Heating equipment test
61
Cooling equipment test
62
Auxiliary equipment test (HP only)
63
Fan equipment test
Test Number
Humidistat System Test
70
Humidification equipment test
71
Dehumidification equipment test
12
The test number is displayed on the upper left, and the
output state is displayed in the message center .
press
to turn on the output (01). For multi stage
output, press
again to turn on the 2nd stage (02).
press
to turn off all the outputs (00).
press [bACK] or [NEXT] to change to the next test
step .
When the last step is done, press [NEXT] . The
message "installer test complete" will display .
All minimum on and off timers will be reset after
returning from system test mode .
Note: Second stage will only be displayed when the
thermostat is set to multi-stage mode .
SETUp & TESTINg

SYSTEM TEST TAblES

Test 60: Heating Equipment Test
button
Equipment
Heat
Stages
w
press
Type
Type
Gas
ON
Heat Cool
1st Up
Electric
ON
press
Heat Pump
1
Heat Cool
Gas
ON
2
2nd Up
Electric
ON
press
1
Heat Pump
2
Test 61: Cooling Equipment Test
button
Equipment
Stages
w
press
Type
Heat Cool
1st Up
press
Heat Pump
1
Heat Cool
2
2nd Up
press
1
Heat Pump
2
Test 62: Auxiliary Equipment Test (HP only)
button
Equipment
Heat
w
press
Type
Type
Gas
ON
1st Up
Heat Pump
press
Electric
ON
Gas
ON
2nd Up
Heat Pump
press
Electric
ON
Test 63: Fan Equipment Test
button
w
press
1st Up
press
Test 70: Humidifier Equipment Test
button
w
press
1st Up
ON
press
Test 71: Dehumidifier Equipment Test
button
w
press
1st Up
press
w2
Y
Y2
g
O
ON
ON
ON
ON
ON
ON
ON
ON
ON
w2
Y
Y2
g
O
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
w2
Y
Y2
g
O
ON
ON
ON
ON
w2
Y
Y2
g
O
ON
w2
Y
Y2
g
O
ON
w2
Y
Y2
g
O
ON
ON
ON
b
ON
ON
ON
ON
ON
ON
b
b
ON
ON
ON
ON
b
b
ON
b
13