SYSTEM TEST MODE

The system test mode is used to test a system after installation . The outputs of the thermostat can be manually
activated one at a time to test their function . The following instructions show how to enter the test mode and turn
outputs on and off . The charts on the following pages show the output status for each test step for Heat/Cool and
Heat Pump mode .
The test steps are:
Test Number
Heat/Cool
50
Heating (W) (W2)
51
52
Cooling (Y) (Y2)
53
Fan (G)
16
Heat Pump
Compressor Heating (Y) (Y2)
Aux Heating (W) (W2)
Compressor Cooling (Y) (Y2)
Fan (G)
SETUP & TESTING
SYSTEM TEST MODE
(CONTINUED)
How to enter the system test menu
Press
repeatedly until system is set to OFF .
Press and hold
and
for three seconds .
The screen of the first test step #50 is displayed:
SYSTEM TEST
NUMBER
MODE
(SW1 SETTING)
OUTPUT STATUS
Includes Event-Based
Air Cleaning
Press
to turn on the output (01) . For multi stage
output, press
again to turn on the 2nd stage (02) .
Press
to turn off the output (00) .
Press
to change to the next test step .
Press
after the last test step . "DONE" will be
displayed .
The thermostat will return to Normal mode if no button is
pressed in 3 seconds .